Begin Part Validation | AeccStructCylSlabTopCylFrame_Metric

Begin Part Family self validation test
ERROR: Required Parameter not found: CB-MATERIAL
ERROR: Required Parameter not found: OPSD
ERROR: Required Parameter not found: CB-TYPE
OK: Part Domain parameter validated -- Structure_Domain
ERROR: Part Type parameter not validated
OK: Part Subtype parameter validated -- Slab Top
OK: Part Description parameter validated -- Cylindrical Structure Slab Top Circular Frame SI
OK: Part Name parameter validated -- AeccStructCylSlabTopCylFrame_Metric
OK: Part Size Name parameter found
OK: Unique Part ID  validated -- D0F590F0-0250-436D-B660-347AD681DC3C
OK: Data Version parameter validated, version = 2.0
OK: Sample Expanded Table row successfully created
 
Begin Calc Usage Validation
OK: Calc Parameter PrtSN uses Context=Catalog_PartSizeName
OK: Calc Parameter BdyD1 uses Context=BodyGeometry_Diameter
OK: Calc Parameter BdyD2 uses Context=BodyGeometry_Diameter
OK: Calc Parameter LenB1 uses Context=Geometry_Distance3D
OK: Calc Parameter LenB2 uses Context=Geometry_Distance3D
OK: Calc Parameter SBSD uses Context=StructDiameter
OK: Calc Parameter SBSH uses Context=StructHeight
OK: Calc Parameter SVPC uses Context=StructVertPipeClearance
OK: Calc Parameter WPOf1 uses Context=Geometry_WorkplaneOffset
 
ERROR: Table Data Validation Failed | J:\2022-01-26 - CIVIL 3D Q&A\2019\2019 Pipes Catalog\Metric Structures\Junction Structures with Frames\AeccStructCylSlabTopCylFrame_Metric.xml

ERROR: Part Validation Failed | Junction Structures with Frames\AeccStructCylSlabTopCylFrame_Metric.xml
